Version 7.6 - Released 29th August 2017 - Sym3 Designer and Integrator Only
What’s new
New Equipment: Free Roller Conveyor, see documentation for description, properties and functions. [ref 9695]
Free Roller Conveyor: can be imported using importer macro. [ref 9926]
Importer macro: Shoe Sorter support. [ref 9905]
UI improvement for the creation of datasource. [ref 10045]
New function in simulation script: ResumeSimulation(). [ref 10121]
New Datasource: MC PLC Emulation. Is used to have Sym3 emulate a Mitsubishi PLC. [ref 10002]
Bugs fixed
MC Driver was crashing when tag set as output on a PE Sensor and PE status changed. [ref 9946]
MyEquipment: delete an instance of a MyEquipment type: children were not deleted. [ref 9941]
User Property: user property not updated in PropertyEditor when changed in simulation script. [ref 9944]
Device IO: for Input, if input is ‘Inverted’ and has a Script handler, the value received in the handler if inverted. [ref 9956]
Path: The path speed, acceleration, and deceleration units for the MoveAlongSection function were always meters/sec. Now working also in imperial unit. [ref 9942]
PE not blocked: when diverted by a ‘Diverter’ and PE of destination was too closed to the beginning (less than 0.2m). [ref 9960]
Device: sripheader option set to false was not working when server send message. [ref 9945]
PE sensor: Indicators color not saved in project. [ref 9979]
Menu: couldn’t assign a menu to a MyEquipment in Designer/Integrator. [ref 10003]
Barcode Scanner created on a sorter: the PE was not working (path couldn’t be changed). [ref 9537]
Some PE were visible only on ‘Background’ layer even if they had a layer. [ref 9977]
Device IOs: they stopped working when more than 16 devices defined in project. [ref 9967]
Products: A child product was always in background layer. [ref 10050]
PE not blocked on child products. [ref 10049]
Integrator: update log config file (DeviceIO input not well configured). [ref 10078]
Operator Client: Disable 3D was not working. [ref 10023]
Sorters: PE sensors were not saved at correct position. [ref 10015]
Integrator: Replay was not working for the very first time it was used on a fresh machine due to a folder that didn’t exist. [ref 10073]
MyEquipment: naming issue after saving/loading (simulation script of a MyEquipment couldn’t run). [ref 10095]
CIP: tag always updated even if value doesn’t change. [ref 10104]
Crash with tags having a scripthandler (when tag quality becomes BAD). [ref 9730]
MoveProduct issue with Rack, cannot find Rack by name. [ref 10094]
EStop: button color was not saved in project [ref 10098]
Fixed a regression bug after merging products (they were offset). [ref 10184]
Mitsubishi PLC: a quality of a tag was changing to BAD. [ref 10107]