[O] Web client, possibility to have some parameters to set the camera and to show/hide the left panel. See documentation. [ref 26364, 26477]
[D I O] Some changes applied to the beta equipment for BTS (Merge, Diverge and Transfer) to facilitate the import from AutoCAD. We are working on a native importer for BTS equipment in Sym3 and those code changes were required. No end user functionalities added. [ref 26581, 26529, 26580]
[D I O] The transfer BTS equipment delivered in beta in previous version: type name has been changed from ‘HTRTransfer’ to ‘Transfer’. [ref 26377s]
[D I O] Technical changes - The way simulation scripts are saved in the project has been changed - Nothing new for end user. [ref 24166]
[O] Expressions - Updated logs for more clarity. [ref 24105]
[O] Technical optimisation for Sym3 Operator Client. If the alarm server is disconnected in the client configuration, the loading time will be faster as we don’t load alarm definitions anymore (not needed). [ref 26295]
Bugs fixed
[D I] A PE Sensor was remaining blocked. [JIRA Sym3-399] [ref 26567].
[I] Issue when using normal close devices with Tag. This was due to using binding of User Properties of MyEquipment that was not supported. [JIRA Sym3-340] [ref 19393]
[I] CC-Link: Make V device a bit device, allow negative device numbers. [ref 26439]
[I] CC-Link: Make V device a bit device. [ref 26438]
[I] Fixed a regression due to Undo/Redo. This regression broke SendMessage function in some occasions. [SUPPORT 2163] [ref 26585]